Uninterruptible Power Supply (UPS)
A1 SERIES 1-3 kVA Single phase
SPWM inverter
High input PF (?0.99)
Low output voltage THD (?2%)
Wide input voltage tolerances (-25%, +20%)
Compatible with different load types
Reduced weight/volume/footprint
Cold start
Energy-saving sleep mode
Overload, short circuit, lightning and surge protection
Generator compatibility
Extended battery life with intelligent battery management
Extra charger and battery cabinet for longer back-up time
Automatic battery test
LCD interface and LED operation mode indicator
Remote monitoring panel (optional)
Remote emergency power off (EPO)
F-A2 SERIES 3-5 kVA Single phase
Low investment and operating cost
Short return on investment time
Reduced weight/volume/footprint
Wide input voltage tolerances (-25%, +20%)
Cold start
Energy-saving sleep mode
Short circuit, lightning and surge protection
Remote emergency power off (EPO)
Generator compatibility
1-5A adjustable charger (optional)
Extended battery life with intelligent battery management
Automatic battery test
LCD interface and LED operation mode indicator
Remote monitoring panel (optional)
128 event log
Battery capacity and load percentage display
SNMP (optional) and RS232 communication
Remote monitoring and management software
Dry contacts
A2 SERIES 6-10 kVA Single phase
Low investment and operating cost
Short return on investment time
Reduced weight/volume/footprint
Wide input voltage tolerances (-25%, +20%)
Cold start
Energy-saving sleep mode
Short circuit, lightning and surge protection
Remote emergency power off (EPO)
Generator compatibility
1-5A adjustable charger (optional)
Extended battery life with intelligent battery management
Automatic battery test
LCD interface and LED operation mode indicator
Remote monitoring panel (optional)
128 event log
Battery capacity and load percentage display
SNMP (optional) and RS232 communication
Remote monitoring and management software
Dry contacts
A3 SERIES 10-15-20 kVA Single phase
Programmable high overload capacity
Short circuit protection
Low investment and operation cost
Short return on investment time
Highest efficiency eco-mode (up to 98%)
Reduced weight/volume/footprint
Wide input voltage tolerances (-25%, +20%)
Energy-saving sleep mode
Short circuit, lightning and surge protection
Remote emergency power off (EPO)
Generator compatibility
1-7A adjustable battery charger
Extended battery life with intelligent battery management
Automatic and manual battery test
LCD interface and LED operation mode diagram
Remote monitoring panel (optional)
512 real time event log
Battery capacity, load percentage and ambient temperature display
SNMP (optional), RS232, Modem, MODBUS communication
A4 SERIES 1-10 kVA Single phase
Can be installed on the floor or in rack cabinets for networking applications
Rotatable display
Low investment and operation cost
Short return on investment time
Reduced weight/volume/footprint
Wide input voltage tolerances (-25%, +20%)
Energy-saving sleep mode
Short circuit, lightning and surge protection
Remote emergency power off (EPO)
Extended battery life with intelligent battery management
Automatic and manual battery test
LCD interface and LED operation mode diagram
Remote monitoring panel (optional)
128 real time event log
Battery capacity, load percentage and ambient temperature display
SNMP (optional), RS232 communication
Remote monitoring and management software
Dry contacts and custom inputs
Internal battery
Easy installation and maintenance
2 years warranty
7/24 technical support and customer service
B1 SERIES 10 kVA Three/Single phase
Low investment and operating cost
Short return on investment time
Reduced weight/volume/footprint
Wide input voltage tolerances (-25%, +20%)
Cold start
Energy-saving sleep mode
Short circuit, lightning and surge protection
Remote emergency power off (EPO)
Generator compatibility
1-5A adjustable charger (optional)
Extended battery life with intelligent battery management
Automatic battery test
LCD interface and LED operation mode indicator
Remote monitoring panel (optional)
128 event log
Battery capacity and load percentage display
SNMP (optional) and RS232 communication
Remote monitoring and management software
Dry contacts
Internal battery
B2 SERIES 10-15-20 kVA Three/Single phase
Programmable high overload capacity
Short circuit protection
Low investment and operation cost
Short return on investment time
Highest efficiency eco-mode (up to 98%)
Reduced weight/volume/footprint
Wide input voltage tolerances (-25%, +20%)
Energy-saving sleep mode
Short circuit, lightning and surge protection
Remote emergency power off (EPO)
Generator compatibility
1-7A adjustable battery charger
Extended battery life with intelligent battery management
Automatic and manual battery test
LCD interface and LED operation mode diagram
Remote monitoring panel (optional)
512 real time event log
Battery capacity, load percentage and ambient temperature display
SNMP (optional), RS232, Modem, MODBUS communication
Remote monitoring and management software
C1 SERIES 10 -120 kVA Three phase
Parallel option up to 6 units
Intelligent redundancy management (n, n+1 and n+x)
Variable input low voltage depending on loading percentage (up to -36%)
Programmable high overload capacity
Short circuit protection
Local and remote emergency power off
Dual input (Optional)
Optimum generator compatibility
IGBT rectifier
High efficiency (up to 92%)
High input PF (?0.99)
Low input current THD (?4%)
Low output voltage THD (?2%)
Short response time (?2ms)
High input and output performance
F-C1 SERIES 10 -120 kVA Three phase
Parallel option up to 6 units
Intelligent redundancy management (n, n+1 and n+x)
Variable input low voltage depending on loading percentage (up to -36%)
Programmable high overload capacity
Short circuit protection
Local and remote emergency power off
Dual input (Optional)
Optimum generator compatibility
IGBT rectifier
High efficiency (up to 92%)
High input PF (?0.99)
Low input current THD (?4%)
Low output voltage THD (?2%)
Short response time (?2ms)
High input and output performance
D1 SERIES 160-800 kVA Three phase
Parallel option up to 6 units
Intelligent redundancy management (n, n+1 and n+x)
Variable input low voltage depending on loading percentage (up to -36%)
Programmable high overload capacity
Short circuit protection
Local and remote emergency power off
Dual input(Optional)
Optimum generator compatibility
IGBT rectifier
High efficiency (up to 92%)
High input PF (?0.99)
Low input current THD (?4%)
Low output voltage THD (?2%)
Short response time (?2ms)
High input and output performance
F-D1 SERIES 160-800 kVA Three phase
Parallel option up to 6 units
Intelligent redundancy management (n, n+1 and n+x)
Variable input low voltage depending on loading percentage (up to -36%)
Programmable high overload capacity
Short circuit protection
Local and remote emergency power off
Dual input(Optional)
Optimum generator compatibility
IGBT rectifier
High efficiency (up to 92%)
High input PF (?0.99)
Low input current THD (?4%)
Low output voltage THD (?2%)
Short response time (?2ms)
High input and output performance
E1 SERIES 10-20 kVA Three phase
Parallel option up to 4 units
Intelligent redundancy management (n, n+1 and n+x)
Programmable high overload capacity
Short circuit protection
Low investment and operation cost
Short return on investment time
Highest efficiency eco-mode (up to 98%)
Reduced weight/volume/footprint
Wide input voltage tolerances (-25%, +20%)
Energy-saving sleep mode
Short circuit, lightning and surge protection
Remote emergency power off (EPO)
Generator compatibility
1-7A adjustable battery charger
Extended battery life with intelligent battery management
Automatic and manual battery test
LCD interface
Remote monitoring panel (optional)
512 real time event log
Battery capacity, load percentage and ambient temperature display
SNMP (optional), RS232, RS485, Modem, MODBUS communication
F-E1 SERIES 10-20 kVA Three phase
Parallel option up to 4 units
Intelligent redundancy management (n, n+1 and n+x)
Programmable high overload capacity
Short circuit protection
Low investment and operation cost
Short return on investment time
Highest efficiency eco-mode (up to 98%)
Reduced weight/volume/footprint
Wide input voltage tolerances (-25%, +20%)
Energy-saving sleep mode
Short circuit, lightning and surge protection
Remote emergency power off (EPO)
Generator compatibility
1-7A adjustable battery charger
Extended battery life with intelligent battery management
Automatic and manual battery test
LCD interface
Remote monitoring panel (optional)
512 real time event log
Battery capacity, load percentage and ambient temperature display
SNMP (optional), RS232, RS485, Modem, MODBUS communication
E2 SERIES 30-200 kVA Three phase
Low investment and operating cost
Short return on investment time
Higher efficiency with eco-mode (up to 98%)
Reduced weight/volume/footprint
Touch screen TFT LCD user interface
Multi language options up to 10 languages
Advance data and event log
1024 real time event log and easy download
Data analyzing over user interface
Multi communication options
RS232/RS485 (standard)
USB Port (standard)
SNMP (standard)
Advance monitoring options (standard)
Remote monitoring and management software
Programmable dry contacts
Optimum generator compatibility
Long battery life with intelligent battery management
Flexible battery count
Automatic and manual battery test
Smart fan control
2 years warranty
7/24 technical support and customer service
E3 SERIES 10-800 kVA Three phase
Low investment and operating cost
Short return on investment time
Reduced weight/volume/footprint
Higher efficiency with eco-mode (up to 98%)
Self-loading (regenerative mode)
Adjustable input / output voltage & selectable frequency
Extended battery life with intelligent battery management
Automatic and manual battery test with adjustable period and duration
o Touch screen TFT LCD user interface
RS232/RS485
USB Port
SNMP
Advance monitoring options
1024 real time event log and easy download
Multi language options
Remote monitoring and management software
Programmable dry contacts
Custom inputs
Maintenance bypass
Easy installation and maintenance
2 years warranty